GE SR750 PDF

GE MULTILIN SR FEEDER MANAGEMENT RELAY NEW VAC. General Electric P5-G5-S5-HI-AR-E. General Electric GE MULTILIN SR GE MULTILIN SR FEEDER MANAGEMENT RELAY NEW VAC, WITH CASE. General Electric P5-G5-S5-HI-AR-T-H. General Electric GE. Find great deals for GE Multilin Feeder Management Relay Sr Shop with confidence on eBay!.

Author: Vuzuru Shaktirg
Country: Cape Verde
Language: English (Spanish)
Genre: Photos
Published (Last): 10 December 2014
Pages: 42
PDF File Size: 15.54 Mb
ePub File Size: 14.45 Mb
ISBN: 183-5-65132-406-5
Downloads: 79794
Price: Free* [*Free Regsitration Required]
Uploader: Tasar

The VT failure feature monitors each phase of input voltage, generating an alarm and sending the programmed output signals when a failure is detected. Events may be recorded selectively by category, so that only events of interest are recorded.

With the new 8 Series Retrofit Kit users are able to install the Feeder Management System without modifying existing cutouts and wiring, and without any drawing rs750 or re-engineering time.

GE SR750 Multilin Power Management Reconditioned

Trace memory recording can be triggered by operation of selected features or logic inputs. Records of the last 10 faults are stored.

Breaker Conditions The relay calculates the per-phase wear on the breaker contacts to establish a threshold.

This easy to use relay provides comprehensive protection functions for feeders and back up protection for bus, transformers and transmission lines at a reduced product life cycle cost. A sr7500 Ethernet port is also available as an optional feature. No need to disconnect any of the field wiring.

A 40 character display allows access to setpoints, actual values, and diagnostic messages generated by a trip or alarm condition. The number of breaker trip operations is recorded, and can be displayed for statistical purposes useful for units without operation counters.

When the measured quantity exceeds the pickup level, the relay can trigger an alarm or signal an output. Fault Locator The relay uses captured data to calculate the type, distance to and the impedance of the fault.

  LIVIDEZ CADAVERICA PDF

As an dr750, please refer to the relay. Indicators Twenty LEDs indicate relay status, system status, and trip and alarm conditions. This memory can be configured between the ranges of two to 16 blocks with 16 to power frequency cycles of data respectively. Analog Inputs Any external quantity may be monitored via an auxiliary current input.

EnerVista 8 Series Setup Software provides automated setting file conversion. The relay uses captured data to calculate the type, distance to and the impedance of the fault. Event Recording The relay captures and stores the last events, recording the time, date, cause, and system parameters. Load shedding schemes based on voltage and frequency elements Back-up protection for transmission lines, feeders and transformers Distributed Generation DG interconnect protection.

User Interface Various user interfaces facilitate operation of the Two analog input level monitoring elements and two rate-of-change elements are available.

Convenient COMTRADE and Sequence of Events viewers are an integral part of the Setup software included with every relay, to carry out postmortem event analysis to ensure proper protection system operation. Insert the new 8 Series Retrofit chassis into the switchgear and simply plug-in the old terminal blocks – there is no need to make any cut-out modifications or push and pull cables. The relay calculates the per-phase wear on the breaker contacts to establish a threshold.

Orders may be placed until 31st Decemberand will be fulfilled based upon availability. Trip Counter The number of breaker trip operations is recorded, and can be displayed for statistical purposes useful for units without operation counters.

A failure to respond to an open or close signal in a programmed time can be used to generate an alarm. Traditionally, retrofitting an existing relay has been a challenging, time consuming task often requiring re-engineering, new drawings, panel modifications, re-wiring and re-testing.

General Electric GE MULTILIN SR FEEDER MANAGEMENT RELAY NEW

The relay captures and stores the last events, recording the time, date, cause, and system parameters. VT Failure The VT failure feature monitors each phase of input voltage, generating an alarm and sending the programmed output signals when a failure is detected. The front panel port allows easy local computer access.

  CORNING CCH-04U PDF

Once completed, a graphical report is provided to verify and call out any specific settings that may need attention. An alarm is also generated if the relay detects that the supervisory trickle current is not present. When the breaker maintenance threshold is exceeded the relay can trigger an alarm. Grid Solutions helps enable utilities and industry to effectively manage electricity from the point of generation to the point of consumption, helping to maximize the reliability, efficiency and resiliency of the grid.

Any external quantity may be monitored via an auxiliary current input.

Oscillography A block of configurable volatile memory can be used for recording samples of the AC input voltages and current, and sr7500 status of logic inputs and output relays.

A block of configurable volatile memory can be used for recording samples of the AC input voltages and current, and the status of logic inputs and output relays. Simply remove the terminal blocks and then remove the SR chassis from the panel.

The amount of pre-event data recorded is set by the user. The baud rate of all the gr ports is variable from to 19, bps.

/ Feeder Management Relay

About Grid Solutions GE’s Grid Solutions business serves customers globally with over 17, employees in approximately 80 countries. Display A 40 character display allows access to setpoints, actual values, and diagnostic messages generated by a trip or alarm condition. This product is under last-time buy. The can display sr70 user-selected messages during keypad inactivity.